Questions & Answers

FORTIN RFK411

0 votes
Hi, again before 5 months i have installed EVO-ALL with NIST1 on Murano 2009. I can start the car wirh OEM FOB (3xLOCK) but can not stopped it or unlock it with the FOB. It can unlock it with the phisical key and when oped the the door the engine stopped. I had done connections to the BCM module(LOCK/UNLOCK pins).

Now i have installed Fortin RFK411. I can start and stop the engine but still can not unlock the car when engine is remotely started. I can not lock or unlock the cars when car is NOT started with Fortin remotes.

I have one question- if i make connections for LOCK/UNLOCK not to BCM, but directly to the drivers door button for LOCK/UNLOCK.

Please make advise!
posté Mai 17, 2023 dans la catégorie Nissan par Dobromir Dimitrov (450 points)

1 Réponse

0 votes
 
Meilleure réponse
Hello,

 

Yes you can also make the connections in the drivers door if you choose.

I would suggest testing your wires firs tthough. If you pulse the wires manually you should be able to lock/unlock the vehicle.

 

Best regards.
répondu Mai 17, 2023 par derek g (340,410 points)
élue Mai 18, 2023 par Dobromir Dimitrov
OK. Do you know which pins are for lock and unlock?
It is shown in the installation guide: https://fortin.ca/download/92941/evo-all_ig_tsa_bi_nis-murano_2009_pts_a_92941.pdf

 

For the 411 do not forget, 1 press = lock, 2 presses = unlock

 

Best regards
...